ORVALDI V1000 online 1U LED, ORVALDI V1000(L), V2000(L), V3000, V3000(L) online 2U LCD, V6000, VR10K online 3U LCD

Seria: On-line

Vďaka dvojitej konverzií ORVALDI V on-line poskytuje výkonnú a celkovú ochranu citlivých prístrojov. Môže prijať širšie vstupné napätie. Ideálna ochrana pre Vaše servery a pracovné stanice.

Výrobca: ORVALDI
Kód produktu: VCA1KR, VGA1KRT, VGA1KLRT, VGA2KRT, VGA2KLRT, VGA3KRT, VGA3KLRT, VGAR6K, VGAR10K
ORVALDI V1000 online 1U LED, ORVALDI V1000(L), V2000(L), V3000, V3000(L) online 2U LCD, V6000, VR10K online 3U LCD
ORVALDI V1000 online 1U LED, ORVALDI V1000(L), V2000(L), V3000, V3000(L) online 2U LCD, V6000, VR10K online 3U LCD
ORVALDI V1000 online 1U LED, ORVALDI V1000(L), V2000(L), V3000, V3000(L) online 2U LCD, V6000, VR10K online 3U LCD
ORVALDI V1000 online 1U LED, ORVALDI V1000(L), V2000(L), V3000, V3000(L) online 2U LCD, V6000, VR10K online 3U LCD
ORVALDI V1000 online 1U LED, ORVALDI V1000(L), V2000(L), V3000, V3000(L) online 2U LCD, V6000, VR10K online 3U LCD
ORVALDI V1000 online 1U LED, ORVALDI V1000(L), V2000(L), V3000, V3000(L) online 2U LCD, V6000, VR10K online 3U LCD
ORVALDI V1000 online 1U LED, ORVALDI V1000(L), V2000(L), V3000, V3000(L) online 2U LCD, V6000, VR10K online 3U LCD
ORVALDI V1000 online 1U LED, ORVALDI V1000(L), V2000(L), V3000, V3000(L) online 2U LCD, V6000, VR10K online 3U LCD
ORVALDI V1000 online 1U LED, ORVALDI V1000(L), V2000(L), V3000, V3000(L) online 2U LCD, V6000, VR10K online 3U LCD

Charakteristika:

Dvojitá konverzia

Výstupný faktor 0,8

Široký rozsah vstupného napätia (110 až 300 VAC)

Korekcia vstupného faktoru 0,99

Režim ECO na úsporu energie (ECO)

Programovateľný výstup

Núdzové vypnutie (EPO)

Hot-swap batérie

Nabíjačka s rozšírenou kapacitou 8A pre dlhodobé modely

SNMP + USB + RS-232 komunikácia

Inteligentná nabíjačka batérií na optimalizovaný výkon batérie

Voliteľné výstupné napätie pomocou LCD displeju

 

Použitie:

Telekomunikačné systémy, VOIP,

Servery a počítačové siete (pasívne a aktívne PFC)

Meracie a kontrolné prístroje

Lekárske vybavenie

 

 

Product features:

  • True double-conversion online UPS,
  • Output power factor 0.9,
  • Wide input voltage range (160-300V AC),
  • User-friendly LCD,
  • Switching time 0ms,
  • 50Hz/60Hz frequency converter mode,
  • Tower design,
  • Emergency power off function (EPO),
  • Hot-swappable battery,
  • Multiple communication RS232/USB, option SNMP/AS400,
  • Version for a long time battery operation available,

Stiahnuť :

Technické údaje:

Model  / PN

ORVALDI V1000 (L)on-line 2U LCD  /  VGA1K(L)

ORVALDI V2000 (L) on-line 2U LCD  / VGA2K(L) ORVALDI V3000 (L) on-line 2U LCD   / VGA3K(L) ORVALDI V6000 (L) on-line 3U LCD  / VGA6K(L) ORVALDI V10000 (L) on-line 3U LCD   / VGA10K(L)
Phase Single phase with ground
Capacity 1000 VA / 800 W 2000 VA / 1600 W 3000 VA / 2400 W 6000 VA / 4800 W 10000 VA / 8000 VA
INPUT
Frequency Range 45Hz ~ 55 Hz or 56Hz ~ 65 Hz 46~54 Hz or 56~64 Hz
Power Factor ≧ 0.99 ≧ 0.99 @ 100%load
Voltage Range
Low Line Transfer 80 VAC/70 VAC/60 VAC/50 VAC ± 5% or 160 VAC/140 VAC/120 VAC/110 VAC ± 5% (based on load percentage 100% - 80 % / 80 % - 70 % / 70 - 60 % / 60 % - 0) 176 VAC ± 3% @ 100% load ; 110 VAC ± 3% @ 50% load
Low Line Comeback 85 VAC / 75VAC / 65 VAC / 55VAC ± 5 % or 170 VAC /150 VAC/ 130 VAC /120 VAC± 5 % 186 VAC ± 3% @ 100% load ; 120 VAC ± 3% @ 50% load
High Line Transfer 150 VAC ± 5 % or 300 VAC ± 5 % 300 VAC ± 3%
High Line Comeback 145 VAC ± 5 % or 290 VAC ± 5 % 290 VAC ± 3%
OUTPUT
Output Voltage 110/115/120/127 VAC or 208/220/230/240 VAC 208/220/230/240 VAC
AC Voltage Regulation (Batt. Mode) ± 1% ± 1%
Frequency Range (Synchronized Range) 48 ~ 52 Hz or 58 ~ 62 Hz 46~54 Hz or 56~64 Hz
Frequency Range (Batt. Mode) 50 Hz ± 0.2 Hz or 60Hz ± 0.2 Hz 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz
Current Crest Ratio 3:1 3:1
Harmonic Distortion ≦ 2 % THD (Linear Load), 8% max. (Batt. mode before shut down) ≦ 3 % THD (Linear Load) ; ≦ 6 % THD (Non-linear Load)
Waveform (Batt. Mode) Pure Sinewave
Transfer Time
AC Mode to Batt. Mode Zero
Inverter to Bypass 4 ms (Typical) Zero
EFFICIENCY
AC Mode 86% 88% 89%
Battery Mode 83% 85% 88%
BATTERY
Standard Model
Battery Type 12 V / 9 Ah 12 V / 7 Ah   12 V / 9 Ah 12 V / 7Ah 12 V / 9Ah 12 V / 7 Ah 12 V / 9 Ah
Numbers 2 3*   4 6* 6 20 20
Charging Voltage 27.4 VDC ± 1% 41.1 VDC ± 1%   54.8 VDC ± 1% 82.1 VDC ±1% 82.1 VDC ±1% 273 VDC ±1%
Charging Current (max.) 1.0 A 2.0 A
Typical Recharge Time 4 hours recover to 90% capacity 3 hours recover to 90% capacity 4 hours recover to 90% capacity
Long-run Model
Battery Type Depending on the capacity of external batteries Depending on applications
Numbers Depending on the capacity of external batteries 18-20
Charging Current (max.) 8.0 A 2.0 A
Charging Voltage 27.4 VDC ± 1% 41. 1 VDC ± 1%   54.8 VDC ± 1% 82.1 VDC ±1% 82.1 VDC ±1% 273.0 VDC ±1%
INDICATORS
LCD Display UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions
ALARM
Battery Mode Sounding every 4 seconds
Low Battery Sounding every second
Overload Sounding twice every second
Fault Continuously sounding
PHYSICAL
Standard Model
Dimension, D x W x H (mm) 380 x 438 x 88 [2U] 480 x 438 x 88 [2U]   480 x 438 x 88 [2U] 600 x 438 x 88 [2U] 600 x 438 x 88 [2U] UPS Unit : 580 x 438 x133 [3U] ; Battery Pack : 580 x 438 x 133 [3U] UPS Unit: 668 x 438 x 133 [3U] ; Battery Pack : 580 x438 x 133 [3U]
Net Weight (kgs) 13.2 18.4   20.6 25.7 29 UPS Unit : 17 ; Battery Pack : 57 UPS Unit : 20 ; Battery Pack : 63
Long-run Model
Dimension, D x W x H (mm) 380 x 438 x 88 [2U] 480 x 438 x 88 [2U]   480 x 438 x 88 [2U] 600 x 438 x 88 [2U] 600 x 438 x 88 [2U] 580 x 438 x 133 [3U] 668 x 438 x 133 [3U]
Net Weight (kgs) 9.1 11.3   11.3 14.6 14.8 17 20
ENVIRONMENT
Humidity 20-90 % RH @ 0- 40°C (non-condensing)
Noise Level Less than 50dB @ 1 Meter Less than 55dBA @ 1 Meter Less than 58dBA @ 1 Meter
MANAGEMENT
Optional SNMP Power management from SNMP manager and web browser
Smart RS-232/USB Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7, Linux, Unix, and MAC

*In LV system, only 12V/7Ah x 3 for 1K model and 12V/7Ah x 6 for 2K model are available.
NOTE 1: Derate to 60% of capacity in CVCF mode and to 90% when the output voltage is adjusted to 208VAC.
NOTE 2: If the UPS is installed or used in a place where the altitude is above than 1000m, the output power must be derated one percent per 100m.
** L means long-run model